IPC-Stelle: H02P 31/00 [Version 2017.01]

SymbolTypTitel
HSKELECTRICITY
H02KLGENERATION, CONVERSION, OR DISTRIBUTION OF ELECTRIC POWER
H02PUKLCONTROL OR REGULATION OF ELECTRIC MOTORS, ELECTRIC GENERATORS OR DYNAMO-ELECTRIC CONVERTERSCONTROLLING TRANSFORMERS, REACTORS OR CHOKE COILS [4]
H02P 1/00HGRArrangements for starting electric motors or dynamo-electric converters (starting of synchronous motors with electronic commutators H02P 6/20, H02P 6/22; starting dynamo-electric motors rotating step by step H02P 8/04; vector control H02P 21/00) [1, 4, 2006.01]
H02P 1/02UGR1
.Details [1, 2006.01]
H02P 1/04UGR2
. .Means for controlling progress of starting sequence in dependence upon time or upon current, speed, or other motor parameter [1, 2006.01]
H02P 1/06UGR3
. . .Manually-operated multi-position starters [1, 2006.01]
H02P 1/08UGR3
. . .Manually-operated on/off switch controlling power-operated multi-position switch or impedances for starting a motor [1, 2006.01]
H02P 1/10UGR3
. . .Manually-operated on/off switch controlling relays or contactors operating sequentially for starting a motor [1, 2006.01]
H02P 1/12UGR3
. . .Switching devices centrifugally operated by the motor [1, 2006.01]
H02P 1/14UGR3
. . .Pressure-sensitive resistors centrifugally operated by the motor [1, 2006.01]
H02P 1/16UGR1
.for starting dynamo-electric motors or dynamo-electric converters [1, 2006.01]
H02P 1/18UGR2
. .for starting an individual dc motor [1, 2006.01]
H02P 1/20UGR3
. . .by progressive reduction of resistance in series with armature winding [1, 2006.01]
H02P 1/22UGR3
. . .in either direction of rotation [1, 2006.01]
H02P 1/24UGR2
. .for starting an individual ac commutator motor (starting of ac/dc commutator motors H02P 1/18) [1, 2006.01]
H02P 1/26UGR2
. .for starting an individual polyphase induction motor [1, 2006.01]
H02P 1/28UGR3
. . .by progressive increase of voltage applied to primary circuit of motor [1, 2006.01]
H02P 1/30UGR3
. . .by progressive increase of frequency of supply to primary circuit of motor [1, 2006.01]
H02P 1/32UGR3
. . .by star/delta switching [1, 2006.01]
H02P 1/34UGR3
. . .by progressive reduction of impedance in secondary circuit [1, 2006.01]
H02P 1/36UGR4
. . . .the impedance being a liquid resistance [1, 2006.01]
H02P 1/38UGR3
. . .by pole-changing [1, 2006.01]
H02P 1/40UGR3
. . .in either direction of rotation [1, 2006.01]
H02P 1/42UGR2
. .for starting an individual single-phase induction motor [1, 2006.01]
H02P 1/44UGR3
. . .by phase-splitting with a capacitor [1, 2006.01]
H02P 1/46UGR2
. .for starting an individual synchronous motor [1, 2006.01]
H02P 1/48UGR3
. . .by pole-changing [1, 2006.01]
H02P 1/50UGR3
. . .by changing over from asynchronous to synchronous operation (H02P 1/48 takes precedence) [1, 2006.01]
H02P 1/52UGR3
. . .by progressive increase of frequency of supply to motor [1, 2006.01]
H02P 1/54UGR2
. .for starting two or more dynamo-electric motors [1, 2006.01]
H02P 1/56UGR3
. . .simultaneously [1, 2006.01]
H02P 1/58UGR3
. . .sequentially [1, 2006.01]
H02P 3/00HGRArrangements for stopping or slowing electric motors, generators, or dynamo-electric converters (stopping of synchronous motors with electronic commutators H02P 6/24; stopping dynamo-electric motors rotating step by step H02P 8/24; vector control H02P 21/00) [1, 2, 4, 2006.01]
H02P 3/02UGR1
.Details [1, 2006.01]
H02P 3/04UGR2
. .Means for stopping or slowing by a separate brake, e.g. friction brake or eddy-current brake [1, 2, 2006.01]
H02P 3/06UGR1
.for stopping or slowing an individual dynamo-electric motor or dynamo-electric converter [1, 2, 2006.01]
H02P 3/08UGR2
. .for stopping or slowing a dc motor [1, 2, 2006.01]
H02P 3/10UGR3
. . .by reversal of supply connections [1, 2006.01]
H02P 3/12UGR3
. . .by short-circuit or resistive braking [1, 2006.01]
H02P 3/14UGR3
. . .by regenerative braking [1, 2006.01]
H02P 3/16UGR3
. . .by combined electrical and mechanical braking [1, 2006.01]
H02P 3/18UGR2
. .for stopping or slowing an ac motor [1, 2, 2006.01]
H02P 3/20UGR3
. . .by reversal of phase sequence of connections to the motor [1, 2006.01]
H02P 3/22UGR3
. . .by short-circuit or resistive braking [1, 2006.01]
H02P 3/24UGR3
. . .by applying dc to the motor [1, 2006.01]
H02P 3/26UGR3
. . .by combined electrical and mechanical braking [1, 2006.01]
H02P 4/00HGRArrangements specially adapted for regulating or controlling the speed or torque of electric motors that can be connected to two or more different electric power supplies (vector control H02P 21/00) [2006.01]
H02P 5/00HGRArrangements specially adapted for regulating or controlling the speed or torque of two or more electric motors (H02P 6/04, H02P 8/40 take precedence) [1, 2006.01, 2016.01]
H02P 5/46UGR1
.for speed regulation of two or more dynamo-electric motors in relation to one another [1, 2006.01]
H02P 5/48UGR2
. .by comparing mechanical values representing the speeds [1, 2006.01, 2016.01]
H02P 5/485UGR3
. . .using differential movement of the two motors, e.g. using differential gearboxes [2016.01]
H02P 5/49UGR3
. . .by intermittently closing or opening electrical contacts [2016.01]
H02P 5/50UGR2
. .by comparing electrical values representing the speeds [1, 2006.01, 2016.01]
H02P 5/505UGR3
. . .using equalising lines, e.g. rotor and stator lines of first and second motors [2016.01]
H02P 5/51UGR3
. . .Direct ratio control [2016.01]
H02P 5/52UGR2
. .additionally providing control of relative angular displacement [1, 2006.01, 2016.01]
H02P 5/54UGR3
. . .Speed and position comparison between the motors by mechanical means [2016.01]
H02P 5/56UGR3
. . .Speed and position comparison between the motors by electrical means [2016.01]
H02P 5/60UGR1
.controlling combinations of dc and ac dynamo-electric motors (H02P 5/46 takes precedence) [2006.01]
H02P 5/68UGR1
.controlling two or more dc dynamo-electric motors (H02P 5/46, H02P 5/60 take precedence) [2006.01]
H02P 5/685UGR2
. .electrically connected in series, i.e. carrying the same current [2006.01]
H02P 5/69UGR2
. .mechanically coupled by gearing [2006.01]
H02P 5/695UGR3
. . .Differential gearing [2006.01]
H02P 5/74UGR1
.controlling two or more ac dynamo-electric motors (H02P 5/46, H02P 5/60 take precedence) [2006.01]
H02P 5/747UGR2
. .mechanically coupled by gearing [2006.01]
H02P 5/753UGR3
. . .Differential gearing [2006.01]
H02P 6/00HGRArrangements for controlling synchronous motors or other dynamo-electric motors using electronic commutation dependent on the rotor positionElectronic commutators therefor (vector control H02P 21/00) [3, 4, 6, 2006.01, 2016.01]
H02P 6/04UGR1
.Arrangements for controlling or regulating the speed or torque of more than one motor (H02P 6/10 takes precedence) [6, 2006.01, 2016.01]
H02P 6/06UGR1
.Arrangements for speed regulation of a single motor wherein the motor speed is measured and compared with a given physical value so as to adjust the motor speed [6, 2006.01]
H02P 6/08UGR1
.Arrangements for controlling the speed or torque of a single motor (H02P 6/10, H02P 6/28 take precedence) [6, 2006.01, 2016.01]
H02P 6/10UGR1
.Arrangements for controlling torque ripple, e.g. providing reduced torque ripple [6, 2006.01]
H02P 6/12UGR1
.Monitoring commutationProviding indication of commutation failure [6, 2006.01]
H02P 6/14UGR1
.Electronic commutators [6, 2006.01, 2016.01]
H02P 6/15UGR2
. .Controlling commutation time [2016.01]
H02P 6/16UGR2
. .Circuit arrangements for detecting position [6, 2006.01, 2016.01]
H02P 6/17UGR3
. . .and for generating speed information [2016.01]
H02P 6/18UGR3
. . .without separate position detecting elements [6, 2006.01, 2016.01]
H02P 6/182UGR4
. . . .using back-emf in windings [2016.01]
H02P 6/185UGR4
. . . .using inductance sensing, e.g. pulse excitation [2016.01]
H02P 6/20UGR1
.Arrangements for starting (H02P 6/08 takes precedence) [6, 2006.01, 2016.01]
H02P 6/21UGR2
. .Open loop start [2016.01]
H02P 6/22UGR2
. .in a selected direction of rotation [6, 2006.01]
H02P 6/24UGR1
.Arrangements for stopping [6, 2006.01]
H02P 6/26UGR1
.Arrangements for controlling single phase motors [2016.01]
H02P 6/28UGR1
.Arrangements for controlling current (H02P 6/10 takes precedence) [2016.01]
H02P 6/30UGR1
.Arrangements for controlling the direction of rotation (H02P 6/22 takes precedence) [2016.01]
H02P 6/32UGR1
.Arrangements for controlling wound field motors, e.g. motors with exciter coils [2016.01]
H02P 6/34UGR1
. Modelling or simulation for control purposes [2016.01]
H02P 7/00HGRArrangements for regulating or controlling the speed or torque of electric DC motors [1, 2, 2006.01, 2016.01]
H02P 7/02UGR1
.the DC motors being of the linear type [2016.01]
H02P 7/025UGR2
. .the DC motors being of the moving coil type, e.g. voice coil motors [2016.01]
H02P 7/03UGR1
.for controlling the direction of rotation of DC motors [2016.01]
H02P 7/06UGR1
.for regulating or controlling an individual dc dynamo-electric motor by varying field or armature current [1, 2006.01]
H02P 7/08UGR2
. .by manual control without auxiliary power [1, 2006.01]
H02P 7/10UGR3
. . .of motor field only [1, 2006.01]
H02P 7/12UGR4
. . . .Switching field from series to shunt excitation or vice versa [1, 2006.01]
H02P 7/14UGR3
. . .of voltage applied to the armature with or without control of field [1, 2006.01]
H02P 7/18UGR2
. .by master control with auxiliary power [1, 2006.01]
H02P 7/20UGR3
. . .using multi-position switch, e.g. drum, controlling motor circuit by means of relays (H02P 7/24, H02P 7/30 take precedence) [1, 2006.01]
H02P 7/22UGR3
. . .using multi-position switch, e.g. drum, controlling motor circuit by means of pilot-motor-operated multi-position switch or pilot-motor-operated variable resistance (H02P 7/24, H02P 7/30 take precedence) [1, 2006.01]
H02P 7/24UGR3
. . .using discharge tubes or semiconductor devices [1, 2006.01]
H02P 7/26UGR4
. . . .using discharge tubes [1, 2006.01]
H02P 7/28UGR4
. . . .using semiconductor devices [1, 2006.01, 2016.01]
H02P 7/281UGR5
. . . . .the DC motor being operated in four quadrants [2016.01]
H02P 7/282UGR5
. . . . .controlling field supply only [4, 2006.01, 2016.01]
H02P 7/285UGR5
. . . . .controlling armature supply only [4, 2006.01, 2016.01]
H02P 7/288UGR6
. . . . . .using variable impedance [4, 2006.01, 2016.01]
H02P 7/29UGR6
. . . . . .using pulse modulation [4, 2006.01, 2016.01]
H02P 7/291UGR7
. . . . . . .with on-off control between two set points, e.g. controlling by hysteresis [2016.01]
H02P 7/292UGR6
. . . . . .using static converters, e.g. AC to DC [4, 2006.01, 2016.01]
H02P 7/293UGR7
. . . . . . .using phase control (H02P 7/295 takes precedence) [2016.01]
H02P 7/295UGR7
. . . . . . .of the kind having one thyristor or the like in series with the power supply and the motor [4, 2006.01, 2016.01]
H02P 7/298UGR5
. . . . .controlling armature and field supplies [4, 2006.01, 2016.01]
H02P 7/30UGR3
. . .using magnetic devices with controllable degree of saturation, i.e. transductors [1, 2006.01]
H02P 7/32UGR3
. . .using armature-reaction-excited machines, e.g. metadyne, amplidyne, rototrol [1, 2006.01]
H02P 7/34UGR3
. . .using Ward-Leonard arrangements [1, 2006.01, 2016.01]
H02P 7/343UGR4
. . . .in which both generator and motor fields are controlled [2016.01]
H02P 7/347UGR4
. . . .in which only the generator field is controlled [2016.01]
H02P 8/00HGRArrangements for controlling dynamo-electric motors rotating step by step [2, 6, 2006.01]
H02P 8/02UGR1
.specially adapted for single-phase or bi-pole stepper motors, e.g. watch-motors, clock-motors [6, 2006.01]
H02P 8/04UGR1
.Arrangements for starting [6, 2006.01]
H02P 8/06UGR2
. .in selected direction of rotation [6, 2006.01]
H02P 8/08UGR2
. .Determining position before starting [6, 2006.01]
H02P 8/10UGR2
. .Shaping pulses for startingBoosting current during starting [6, 2006.01]
H02P 8/12UGR1
.Control or stabilisation of current [6, 2006.01]
H02P 8/14UGR1
.Arrangements for controlling speed or speed and torque (H02P 8/12, H02P 8/22 take precedence) [6, 2006.01]
H02P 8/16UGR2
. .Reducing energy dissipated or supplied [6, 2006.01]
H02P 8/18UGR2
. .Shaping of pulses, e.g. to reduce torque ripple [6, 2006.01]
H02P 8/20UGR2
. .characterised by bidirectional operation [6, 2006.01]
H02P 8/22UGR1
.Control of step sizeIntermediate stepping, e.g. microstepping [6, 2006.01]
H02P 8/24UGR1
.Arrangements for stopping (H02P 8/32 take precedence) [6, 2006.01]
H02P 8/26UGR2
. .Memorising final pulse when stopping [6, 2006.01]
H02P 8/28UGR2
. .Disconnecting power source when stopping [6, 2006.01]
H02P 8/30UGR2
. .Holding position when stopped [6, 2006.01]
H02P 8/32UGR1
.Reducing overshoot or oscillation, e.g. damping [6, 2006.01]
H02P 8/34UGR1
.Monitoring operation (H02P 8/36 takes precedence) [6, 2006.01]
H02P 8/36UGR1
.Protection against faults, e.g. against overheating or step-outIndicating faults [6, 2006.01]
H02P 8/38UGR2
. .the fault being step-out [6, 2006.01]
H02P 8/40UGR1
.Special adaptations for controlling two or more stepping motors [6, 2006.01]
H02P 8/42UGR1
.characterised by non-stepper motors being operated step by step [6, 2006.01]
H02P 9/00HGRArrangements for controlling electric generators for the purpose of obtaining a desired output [1, 2006.01]
H02P 9/02UGR1
.Details [1, 2006.01]
H02P 9/04UGR1
.Control effected upon non-electric prime mover and dependent upon electric output value of the generator (effecting control of the prime mover in general, see the relevant class for such prime mover) [1, 2, 2006.01]
H02P 9/06UGR1
.Control effected upon clutch or other mechanical power transmission means and dependent upon electric output value of the generator (effecting control of the power transmission means, see the relevant class for such means) [1, 2, 2006.01]
H02P 9/08UGR1
.Control of generator circuit during starting or stopping of driving means, e.g. for initiating excitation [1, 2, 2006.01]
H02P 9/10UGR1
.Control effected upon generator excitation circuit to reduce harmful effects of overloads or transients, e.g. sudden application of load, sudden removal of load, sudden change of load [1, 2, 2006.01]
H02P 9/12UGR2
. .for demagnetisingfor reducing effects of remanencefor preventing pole reversal [1, 2, 2006.01]
H02P 9/14UGR1
.by variation of field (H02P 9/08, H02P 9/10 take precedence) [1, 2, 2006.01]
H02P 9/16UGR2
. .due to variation of ohmic resistance in field circuit, using resistances switched in or out of circuit step by step [1, 2006.01]
H02P 9/18UGR3
. . .the switching being caused by a servomotor, measuring instrument, or relay [1, 2006.01]
H02P 9/20UGR2
. .due to variation of continuously-variable ohmic resistance [1, 2006.01]
H02P 9/22UGR3
. . .comprising carbon pile resistance [1, 2006.01]
H02P 9/24UGR2
. .due to variation of make-to-break ratio of intermittently-operating contacts, e.g. using Tirrill regulator [1, 2006.01]
H02P 9/26UGR2
. .using discharge tubes or semiconductor devices (H02P 9/34 takes precedence) [1, 2, 2006.01]
H02P 9/28UGR3
. . .using discharge tubes [1, 2006.01]
H02P 9/30UGR3
. . .using semiconductor devices [1, 2006.01]
H02P 9/32UGR2
. .using magnetic devices with controllable degree of saturation (H02P 9/34 takes precedence) [1, 2, 2006.01]
H02P 9/34UGR2
. .using magnetic devices with controllable degree of saturation in combination with controlled discharge tube or controlled semiconductor device [1, 2006.01]
H02P 9/36UGR2
. .using armature-reaction-excited machines [1, 2006.01]
H02P 9/38UGR2
. .Self-excitation by current derived from rectification of both output voltage and output current of generator [1, 2006.01]
H02P 9/40UGR1
.by variation of reluctance of magnetic circuit of generator [1, 2006.01]
H02P 9/42UGR1
.to obtain desired frequency without varying speed of the generator [1, 2006.01]
H02P 9/44UGR1
.Control of frequency and voltage in predetermined relation, e.g. constant ratio [1, 2006.01]
H02P 9/46UGR1
.Control of asynchronous generator by variation of capacitor [1, 2006.01]
H02P 9/48UGR1
.Arrangements for obtaining a constant output value at varying speed of the generator, e.g. on vehicle (H02P 9/04-H02P 9/46 take precedence) [3, 2006.01]
H02P 11/00HGRArrangements for controlling dynamo-electric converters [1, 4, 2006.01]
H02P 11/04UGR1
.for controlling dynamo-electric converters having a dc output [1, 2006.01]
H02P 11/06UGR1
.for controlling dynamo-electric converters having an ac output [1, 2006.01]
H02P 13/00HGRArrangements for controlling transformers, reactors or choke coils, for the purpose of obtaining a desired output [1, 4, 2006.01]
H02P 13/06UGR1
.by tap-changingby rearranging interconnections of windings [1, 2006.01]
H02P 13/08UGR1
.by sliding current collector along winding [1, 2006.01]
H02P 13/10UGR1
.by moving core, coil winding, or shield, e.g. by induction regulator [1, 2006.01]
H02P 13/12UGR1
.by varying magnetic bias [1, 2006.01]
H02P 15/00HGRArrangements for controlling dynamo-electric brakes or clutches (vector control H02P 21/00) [1, 2006.01]
H02P 15/02UGR1
.Conjoint control of brakes and clutches [3, 2006.01]
H02P 17/00HGRArrangements for controlling dynamo-electric gears (vector control H02P 21/00) [3, 2006.01]
H02P 21/00HGRArrangements or methods for the control of electric machines by vector control, e.g. by control of field orientation [6, 2006.01, 2016.01]
H02P 21/02UGR1
.specially adapted for optimising the efficiency at low load [2006.01]
H02P 21/04UGR1
.specially adapted for very low speeds [2006.01]
H02P 21/05UGR1
.specially adapted for damping motor oscillations, e.g. for reducing hunting [2006.01]
H02P 21/06UGR1
.Rotor flux based control involving the use of rotor position or rotor speed sensors [2006.01, 2016.01]
H02P 21/08UGR2
. .Indirect field-oriented controlRotor flux feed-forward control [2006.01, 2016.01]
H02P 21/09UGR3
. . .Field phase angle calculation based on rotor voltage equation by adding slip frequency and speed proportional frequency [2016.01]
H02P 21/10UGR2
. .Direct field-oriented controlRotor flux feed-back control [2006.01, 2016.01]
H02P 21/12UGR1
.Stator flux based control involving the use of rotor position or rotor speed sensors [2006.01, 2016.01]
H02P 21/13UGR1
.Observer control, e.g. using Luenberger observers or Kalman filters [2006.01]
H02P 21/14UGR1
.Estimation or adaptation of machine parameters, e.g. flux, current or voltage [2006.01, 2016.01]
H02P 21/16UGR2
. .Estimation of constants, e.g. the rotor time constant [2016.01]
H02P 21/18UGR2
. .Estimation of position or speed [2016.01]
H02P 21/20UGR2
. .Estimation of torque [2016.01]
H02P 21/22UGR1
.Current control, e.g. using a current control loop [2016.01]
H02P 21/24UGR1
.Vector control not involving the use of rotor position or rotor speed sensors [2016.01]
H02P 21/26UGR2
. .Rotor flux based control [2016.01]
H02P 21/28UGR2
. .Stator flux based control [2016.01]
H02P 21/30UGR3
. . .Direct torque control [DTC] or field acceleration method [FAM] [2016.01]
H02P 21/32UGR2
. .Determining the initial rotor position (H02P 21/34 takes precedence) [2016.01]
H02P 21/34UGR1
.Arrangements for starting [2016.01]
H02P 21/36UGR1
.Arrangements for braking or slowingFour quadrant control [2016.01]
H02P 23/00HGRArrangements or methods for the control of AC motors characterised by a control method other than vector control [2006.01, 2016.01]
H02P 23/02UGR1
.specially adapted for optimising the efficiency at low load [2006.01]
H02P 23/03UGR1
.specially adapted for very low speeds [2006.01]
H02P 23/04UGR1
.specially adapted for damping motor oscillations, e.g. for reducing hunting [2006.01]
H02P 23/06UGR1
.Controlling the motor in four quadrants [2006.01, 2016.01]
H02P 23/07UGR2
. .Polyphase or monophase asynchronous induction motors [2016.01]
H02P 23/08UGR1
.Controlling based on slip frequency, e.g. adding slip frequency and speed proportional frequency [2006.01]
H02P 23/10UGR1
.Controlling by adding a dc current [2006.01]
H02P 23/12UGR1
.Observer control, e.g. using Luenberger observers or Kalman filters [2006.01]
H02P 23/14UGR1
.Estimation or adaptation of motor parameters, e.g. rotor time constant, flux, speed, current or voltage [2006.01]
H02P 23/16UGR1
.Controlling the angular speed of one shaft (H02P 23/18 takes precedence) [2016.01]
H02P 23/18UGR1
.Controlling the angular speed together with angular position or phase [2016.01]
H02P 23/20UGR1
.Controlling the acceleration or deceleration [2016.01]
H02P 23/22UGR1
.Controlling the speed digitally using a reference oscillator, a speed proportional pulse rate feedback and a digital comparator [2016.01]
H02P 23/24UGR1
.Controlling the direction, e.g. clockwise or counterclockwise [2016.01]
H02P 23/26UGR1
.Power factor control [PFC] [2016.01]
H02P 23/28UGR1
.Controlling the motor by varying the switching frequency of switches connected to a DC supply and the motor phases [2016.01]
H02P 23/30UGR1
.Direct torque control [DTC] or field acceleration method [FAM] [2016.01]
H02P 25/00HGRArrangements or methods for the control of AC motors characterised by the kind of AC motor or by structural details [2006.01]
H02P 25/02UGR1
.characterised by the kind of motor [2006.01, 2016.01]
H02P 25/022UGR2
. .Synchronous motors (H02P 25/064 takes precedence) [2016.01]
H02P 25/024UGR3
. . .controlled by supply frequency [2016.01]
H02P 25/026UGR4
. . . .thereby detecting the rotor position [2016.01]
H02P 25/028UGR3
. . .with four quadrant control [2016.01]
H02P 25/03UGR3
. . .with brushless excitation [2016.01]
H02P 25/032UGR2
. .Reciprocating, oscillating or vibrating motors [2016.01]
H02P 25/034UGR3
. . .Voice coil motors (voice coil motors driven by DC H02P 7/025) [2016.01]
H02P 25/04UGR2
. .Single phase motors, e.g. capacitor motors [2006.01]
H02P 25/06UGR2
. .Linear motors [2006.01, 2016.01]
H02P 25/062UGR3
. . .of the induction type [2016.01]
H02P 25/064UGR3
. . .of the synchronous type [2016.01]
H02P 25/066UGR4
. . . .of the stepping type [2016.01]
H02P 25/08UGR2
. .Reluctance motors [2006.01, 2016.01]
H02P 25/083UGR3
. . .Arrangements for increasing the switching speed from one coil to the next one [2016.01]
H02P 25/086UGR3
. . .Commutation [2016.01]
H02P 25/089UGR4
. . . .Sensorless control (direct torque control H02P 23/30) [2016.01]
H02P 25/092UGR3
. . .Converters specially adapted for controlling reluctance motors [2016.01]
H02P 25/098UGR3
. . .Arrangements for reducing torque ripple [2016.01]
H02P 25/10UGR2
. .Commutator motors, e.g. repulsion motors [2006.01]
H02P 25/12UGR3
. . .with shiftable brushes [2006.01]
H02P 25/14UGR3
. . .Universal motors (H02P 25/12 takes precedence) [2006.01]
H02P 25/16UGR1
.characterised by the circuit arrangement or by the kind of wiring [2006.01]
H02P 25/18UGR2
. .with arrangements for switching the windings, e.g. with mechanical switches or relays [2006.01]
H02P 25/20UGR3
. . .for pole-changing [2006.01]
H02P 25/22UGR2
. .Multiple windingsWindings for more than three phases [2006.01]
H02P 25/24UGR2
. .Variable impedance in stator or rotor circuit [2006.01]
H02P 25/26UGR3
. . .with arrangements for controlling secondary impedance [2006.01]
H02P 25/28UGR2
. .using magnetic devices with controllable degree of saturation, e.g. transductors [2006.01]
H02P 25/30UGR2
. .the motor being controlled by a control effected upon an ac generator supplying it [2006.01]
H02P 25/32UGR2
. .using discharge tubes [2006.01]
H02P 27/00HGRArrangements or methods for the control of AC motors characterised by the kind of supply voltage (of two or more motors H02P 5/00; of synchronous motors with electronic commutators H02P 6/00; of DC motors H02P 7/00; of stepping motors H02P 8/00) [2006.01]
H02P 27/02UGR1
.using supply voltage with constant frequency and variable amplitude [2006.01, 2016.01]
H02P 27/024UGR2
. .using AC supply for only the rotor circuit or only the stator circuit [2016.01]
H02P 27/04UGR1
.using variable-frequency supply voltage, e.g. inverter or converter supply voltage [2006.01, 2016.01]
H02P 27/048UGR2
. .using AC supply for only the rotor circuit or only the stator circuit [2016.01]
H02P 27/05UGR2
. .using AC supply for both the rotor and the stator circuits, the frequency of supply to at least one circuit being variable [2006.01]
H02P 27/06UGR2
. .using dc to ac converters or inverters (H02P 27/05 takes precedence) [2006.01]
H02P 27/08UGR3
. . .with pulse width modulation [2006.01]
H02P 27/10UGR4
. . . .using bang-bang controllers [2006.01]
H02P 27/12UGR4
. . . .pulsing by guiding the flux vector, current vector or voltage vector on a circle or a closed curve, e.g. for direct torque control [2006.01]
H02P 27/14UGR4
. . . .with three or more levels of voltage [2006.01]
H02P 27/16UGR2
. .using ac to ac converters without intermediate conversion to dc (H02P 27/05 takes precedence) [2006.01]
H02P 27/18UGR3
. . .varying the frequency by omitting half waves [2006.01]
H02P 29/00HGRArrangements for regulating or controlling electric motors, appropriate for both AC and DC motors (arrangements for starting electric motors H02P 1/00; arrangements for stopping or slowing electric motors H02P 3/00; control of motors that can be connected to two or more different electric power supplies H02P 4/00; regulating or controlling the speed or torque of two or more electric motors H02P 5/00; vector control H02P 21/00) [2006.01, 2016.01]
H02P 29/02UGR1
.Providing protection against overload without automatic interruption of supply (protection against faults of stepper motors H02P 8/36) [2006.01, 2016.01]
H02P 29/024UGR2
. .Detecting a fault condition, e.g. short circuit, locked rotor, open circuit or loss of load [2016.01]
H02P 29/028UGR3
. . .the motor continuing operation despite the fault condition, e.g. eliminating, compensating for or remedying the fault [2016.01]
H02P 29/032UGR2
. .Preventing damage to the motor, e.g. setting individual current limits for different drive conditions [2016.01]
H02P 29/04UGR1
.by means of a separate brake [2006.01]
H02P 29/10UGR1
.for preventing overspeed or under speed [2016.01]
H02P 29/20UGR1
.for controlling one motor used for different sequential operations [2016.01]
H02P 29/40UGR1
.Regulating or controlling the amount of current drawn or delivered by the motor for controlling the mechanical load [2016.01]
H02P 29/50UGR1
.Reduction of harmonics [2016.01]
H02P 29/60UGR1
.Controlling or determining the temperature of the motor or of the drive (H02P 29/02 takes precedence) [2016.01]
H02P 29/62UGR2
. .for raising the temperature of the motor [2016.01]
H02P 29/64UGR2
. .Controlling or determining the temperature of the winding [2016.01]
H02P 29/66UGR2
. .Controlling or determining the temperature of the rotor [2016.01]
H02P 29/68UGR2
. .based on the temperature of a drive component or a semiconductor component [2016.01]
H02P 31/00HGRArrangements for regulating or controlling electric motors not provided for in groups H02P 1/00-H02P 5/00, H02P 7/00 or H02P 21/00-H02P 29/00 [2006.01]
H02P 101/00ZWIndexing scheme associated with groups relating to the arrangements for controlling electric generators [2015.01]
H02P 101/00HGRSpecial adaptation of control arrangements for generators [2015.01]
H02P 101/10UGR1
.for water-driven turbines [2015.01]
H02P 101/15UGR1
.for wind-driven turbines [2015.01]
H02P 101/20UGR1
.for steam-driven turbines [2015.01]
H02P 101/25UGR1
.for combustion engines [2015.01]
H02P 101/30UGR1
.for aircraft [2015.01]
H02P 101/35UGR1
.for ships [2015.01]
H02P 101/40UGR1
.for railway vehicles [2015.01]
H02P 101/45UGR1
.for motor vehicles, e.g. car alternators [2015.01]
H02P 103/00HGRControlling arrangements characterised by the type of generator [2015.01]
H02P 103/10UGR1
.of the asynchronous type [2015.01]
H02P 103/20UGR1
.of the synchronous type [2015.01]