G | SK | PHYSICS |
G01 | USK | INSTRUMENTS |
G01 | KL | MEASURING; TESTING |
G01T | UKL | MEASUREMENT OF NUCLEAR OR X-RADIATION (radiation analysis of materials, mass spectrometry G01N 23/00; tubes for determining the presence, intensity, density or energy of radiation or particles H01J 47/00) |
G01T 1/00 | HGR | Measuring X-radiation, gamma radiation, corpuscular radiation, or cosmic radiation (G01T 3/00, G01T 5/00 take precedence) [1, 2, 2006.01] |
G01T 1/02 | UGR1 | . | Dosimeters (G01T 1/15 takes precedence) [1, 2, 2006.01] |
|
G01T 1/04 | UGR2 | |
G01T 1/06 | UGR2 | . . | Glass dosimeters [1, 2006.01] |
|
G01T 1/08 | UGR2 | . . | Photographic dosimeters [1, 2006.01] |
|
G01T 1/10 | UGR2 | . . | Luminescent dosimeters [1, 2006.01] |
|
G01T 1/105 | UGR3 | . . . | Read-out devices (G01T 1/115 takes precedence) [2, 2006.01] |
|
G01T 1/11 | UGR3 | . . . | Thermo-luminescent dosimeters [1, 2006.01] |
|
G01T 1/115 | UGR4 | . . . . | Read-out devices [2, 2006.01] |
|
G01T 1/12 | UGR2 | . . | Calorimetric dosimeters [1, 2006.01] |
|
G01T 1/14 | UGR2 | . . | Electrostatic dosimeters (construction of ionisation chambers H01J 47/02) [1, 2006.01] |
|
G01T 1/142 | UGR3 | . . . | Charging devices; Read-out devices [2, 2006.01] |
|
G01T 1/15 | UGR1 | . | Instruments in which pulses generated by a radiation detector are integrated, e.g. by a diode pump circuit [1, 2006.01] |
|
G01T 1/16 | UGR1 | . | Measuring radiation intensity (G01T 1/29 takes precedence) [1, 2, 2006.01] |
|
G01T 1/161 | UGR2 | . . | Applications in the field of nuclear medicine, e.g. in vivo counting [2, 2006.01] |
|
G01T 1/163 | UGR3 | . . . | Whole-body counters [2, 2006.01] |
|
G01T 1/164 | UGR3 | . . . | Scintigraphy [2, 2006.01] |
|
G01T 1/166 | UGR4 | . . . . | involving relative movement between detector and subject [2, 2006.01] |
|
G01T 1/167 | UGR2 | . . | Measuring radioactive content of objects, e.g. contamination (whole-body counters G01T 1/163) [2, 2006.01] |
|
G01T 1/169 | UGR2 | . . | Exploration, location of contaminated surface areas [2, 2006.01] |
|
G01T 1/17 | UGR2 | . . | Circuit arrangements not adapted to a particular type of detector [1, 2006.01] |
|
G01T 1/172 | UGR3 | . . . | with coincidence circuit arrangements (G01T 1/178 takes precedence) [2, 2006.01] |
|
G01T 1/175 | UGR3 | . . . | Power supply circuits [2, 2006.01] |
|
G01T 1/178 | UGR3 | . . . | for measuring specific activity in the presence of other radioactive substances, e.g. natural, in the air or in liquids such as rain-water [2, 2006.01] |
|
G01T 1/18 | UGR2 | . . | with counting-tube arrangements, e.g. with Geiger counters (tubes H01J 47/00) [1, 2006.01] |
|
G01T 1/185 | UGR2 | . . | with ionisation-chamber arrangements [2, 2006.01] |
|
G01T 1/20 | UGR2 | . . | with scintillation detectors [1, 2006.01] |
|
G01T 1/202 | UGR3 | . . . | the detector being a crystal [1, 2006.01] |
|
G01T 1/203 | UGR3 | . . . | the detector being made of plastics [1, 2006.01] |
|
G01T 1/204 | UGR3 | . . . | the detector being a liquid [1, 2006.01] |
|
G01T 1/205 | UGR3 | . . . | the detector being a gas [1, 2006.01] |
|
G01T 1/208 | UGR3 | . . . | Circuits specially adapted for scintillation detectors, e.g. for the photo-multiplier section [2, 2006.01] |
|
G01T 1/22 | UGR2 | . . | with Cerenkov detectors [1, 2006.01] |
|
G01T 1/24 | UGR2 | . . | with semiconductor detectors [1, 2006.01] |
|
G01T 1/26 | UGR2 | . . | with resistance detectors [1, 2006.01] |
|
G01T 1/28 | UGR2 | . . | with secondary-emission detectors [1, 2006.01] |
|
G01T 1/29 | UGR1 | . | Measurement performed on radiation beams, e.g. position or section of the beam; Measurement of spatial distribution of radiation [2, 2006.01] |
|
G01T 1/30 | UGR1 | . | Measuring half-life of a radioactive substance [1, 2006.01] |
|
G01T 1/32 | UGR1 | . | Measuring polarisation of particles [1, 2006.01] |
|
G01T 1/34 | UGR1 | . | Measuring cross-section, e.g. absorption cross-section of particles [1, 2006.01] |
|
G01T 1/36 | UGR1 | . | Measuring spectral distribution of X-rays or of nuclear radiation [1, 2006.01] |
|
G01T 1/38 | UGR2 | . . | Particle discrimination and measurement of relative mass, e.g. by measurement of loss of energy with distance (dE/dx) [2, 2006.01] |
|
G01T 1/40 | UGR2 | . . | Stabilisation of spectrometers [2, 2006.01] |
|
G01T 3/00 | HGR | Measuring neutron radiation (G01T 5/00 takes precedence) [1, 2, 2006.01] |
G01T 3/02 | UGR1 | . | by shielding other radiation [1, 2006.01] |
|
G01T 3/04 | UGR1 | . | using calorimetric devices [1, 2006.01] |
|
G01T 3/06 | UGR1 | . | with scintillation detectors [2, 2006.01] |
|
G01T 3/08 | UGR1 | . | with semiconductor detectors [2, 2006.01] |
|
G01T 5/00 | HGR | Recording of movements or tracks of particles (spark chambers H01J 47/14); Processing or analysis of such tracks [1, 2, 2006.01] |
G01T 5/02 | UGR1 | . | Processing of tracks; Analysis of tracks [1, 2006.01] |
|
G01T 5/04 | UGR1 | . | Cloud chambers, e.g. Wilson chamber [1, 2006.01] |
|
G01T 5/06 | UGR1 | . | Bubble chambers [1, 2006.01] |
|
G01T 5/08 | UGR1 | |
G01T 5/10 | UGR1 | . | Plates or blocks in which tracks of nuclear particles are made visible by after-treatment, e.g. using photographic emulsion, using mica [1, 2006.01] |
|
G01T 5/12 | UGR1 | . | Circuit arrangements with multi-wire or parallel-plate chambers, e.g. spark chambers (tubes per seH01J 47/00) [2, 2006.01] |
|
G01T 7/00 | HGR | Details of radiation-measuring instruments [1, 2006.01] |
G01T 7/02 | UGR1 | . | Collecting-means for receiving or storing samples to be investigated [1, 2006.01] |
|
G01T 7/04 | UGR2 | . . | by filtration [1, 2006.01] |
|
G01T 7/06 | UGR2 | . . | by electrostatic precipitation (G01T 7/04 takes precedence) [1, 2006.01] |
|
G01T 7/08 | UGR1 | . | Means for conveying samples received [1, 2006.01] |
|
G01T 7/10 | UGR2 | . . | using turntables [1, 2006.01] |
|
G01T 7/12 | UGR1 | . | Provision for actuation of an alarm [1, 2006.01] |
|