IPC-Stelle: G01T [Version 2006.01]

SymbolTypTitel
GSKSECTION G — PHYSICS
G01USKINSTRUMENTS
G01KLMEASURING (counting G06M)TESTING
G01TUKLMEASUREMENT OF NUCLEAR OR X-RADIATION (radiation analysis of materials, mass spectrometry G01N; counters per seG06M, H03K; electric discharge tubes for analysing radiation or particles H01J 40/00, H01J 47/00, H01J 49/00)
G01T 1/00HGRMeasuring X-radiation, gamma radiation, corpuscular radiation, or cosmic radiation (G01T 3/00, G01T 5/00 take precedence) [2]
G01T 1/02UGR1
.Dosimeters (G01T 1/15 takes precedence; measuring exposure time to X-rays H05G 1/28) [2]
G01T 1/04UGR2
. .Chemical dosimeters (G01T 1/06, G01T 1/08 take precedence)
G01T 1/06UGR2
. .Glass dosimeters
G01T 1/08UGR2
. .Photographic dosimeters (photosensitive materials or processes for photographic purposes G03C)
G01T 1/10UGR2
. .Luminescent dosimeters
G01T 1/105UGR3
. . .Read-out devices (G01T 1/115 takes precedence) [2]
G01T 1/11UGR3
. . .Thermo-luminescent dosimeters
G01T 1/115UGR4
. . . .Read-out devices [2]
G01T 1/12UGR2
. .Calorimetric dosimeters
G01T 1/14UGR2
. .Electrostatic dosimeters (construction of ionisation chambers H01J 47/02)
G01T 1/142UGR3
. . .Charging devicesRead-out devices [2]
G01T 1/15UGR1
.Instruments in which pulses generated by a radiation detector are integrated, e.g. by a diode pump circuit (pulse rate meters in general G01R 23/02)
G01T 1/16UGR1
.Measuring radiation intensity (G01T 1/29 takes precedence) [2]
G01T 1/161UGR2
. .Applications in the field of nuclear medicine, e.g. in vivo counting (applying radioactive material to the body A61M 36/00) [2]
G01T 1/163UGR3
. . .Whole-body counters [2]
G01T 1/164UGR3
. . .Scintigraphy (radio isotopes G21G 4/00; tracers G21H 5/00) [2]
G01T 1/166UGR4
. . . .involving relative movement between detector and subject [2]
G01T 1/167UGR2
. .Measuring radioactive content of objects, e.g. contamination (whole-body counters G01T 1/163) [2]
G01T 1/169UGR2
. .Exploration, location of contaminated surface areas (prospecting by the use of nuclear radiation, natural or induced G01V 5/00) [2]
G01T 1/17UGR2
. .Circuit arrangements not adapted to a particular type of detector
G01T 1/172UGR3
. . .with coincidence circuit arrangements (G01T 1/178 takes precedence) [2]
G01T 1/175UGR3
. . .Power supply circuits (converters H02M) [2]
G01T 1/178UGR3
. . .for measuring specific activity in the presence of other radioactive substances, e.g. natural, in the air or in liquids such as rain-water [2]
G01T 1/18UGR2
. .with counting-tube arrangements, e.g. with Geiger counters (tubes H01J 47/00)
G01T 1/185UGR2
. .with ionisation-chamber arrangements (construction of ionisation chambers H01J 47/02) [2]
G01T 1/20UGR2
. .with scintillation detectors
G01T 1/202UGR3
. . .the detector being a crystal
G01T 1/203UGR3
. . .the detector being made of plastics
G01T 1/204UGR3
. . .the detector being a liquid
G01T 1/205UGR3
. . .the detector being a gas
G01T 1/208UGR3
. . .Circuits specially adapted for scintillation detectors, e.g. for the photo-multiplier section [2]
G01T 1/22UGR2
. .with Cerenkov detectors
G01T 1/24UGR2
. .with semiconductor detectors (semiconductor detectors per seH01L 31/00)
G01T 1/26UGR2
. .with resistance detectors
G01T 1/28UGR2
. .with secondary-emission detectors (secondary-electron-emitting electrodes in general H01J 1/32)
G01T 1/29UGR1
.Measurement performed on radiation beams, e.g. position or section of the beamMeasurement of spatial distribution of radiation (scintigraphy G01T 1/164) [2]
G01T 1/30UGR1
.Measuring half-life of a radioactive substance
G01T 1/32UGR1
.Measuring polarisation of particles
G01T 1/34UGR1
.Measuring cross-section, e.g. absorption cross-section of particles
G01T 1/36UGR1
.Measuring spectral distribution of X-rays or of nuclear radiation
G01T 1/38UGR2
. .Particle discrimination and measurement of relative mass, e.g. by measurement of loss of energy with distance (dE/dx) [2]
G01T 1/40UGR2
. .Stabilisation of spectrometers [2]
G01T 3/00HGRMeasuring neutron radiation (G01T 5/00 takes precedence) [2]
G01T 3/02UGR1
.by shielding other radiation
G01T 3/04UGR1
.using calorimetric devices
G01T 3/06UGR1
.with scintillation detectors [2]
G01T 3/08UGR1
.with semiconductor detectors (semiconductor detectors per seH01L 31/00) [2]
G01T 5/00HGRRecording of movements or tracks of particles (spark chambers H01J 47/00)Processing or analysis of such tracks [2]
G01T 5/02UGR1
.Processing of tracksAnalysis of tracks
G01T 5/04UGR1
.Cloud chambers, e.g. Wilson chamber
G01T 5/06UGR1
.Bubble chambers
G01T 5/08UGR1
.Scintillation chambers (discharge tubes H01J 40/00, H01J 47/00; semiconductor devices H01L)
G01T 5/10UGR1
.Plates or blocks in which tracks of nuclear particles are made visible by after-treatment, e.g. using photographic emulsion, using mica
G01T 5/12UGR1
.Circuit arrangements with multi-wire or parallel-plate chambers, e.g. spark chambers (tubes per seH01J 47/00) [2]
G01T 7/00HGRDetails of radiation-measuring instruments
G01T 7/02UGR1
.Collecting-means for receiving or storing samples to be investigated
G01T 7/04UGR2
. .by filtration
G01T 7/06UGR2
. .by electrostatic precipitation (G01T 7/04 takes precedence)
G01T 7/08UGR1
.Means for conveying samples received
G01T 7/10UGR2
. .using turntables
G01T 7/12UGR1
.Provision for actuation of an alarm