G | SK | PHYSICS |
G01 | USK | INSTRUMENTS |
G01 | KL | MEASURING; TESTING |
G01K | UKL | MEASURING TEMPERATURE; MEASURING QUANTITY OF HEAT; THERMALLY-SENSITIVE ELEMENTS NOT OTHERWISE PROVIDED FOR (radiation pyrometry G01J 5/00) |
G01K 1/00 | HGR | Details of thermometers not specially adapted for particular types of thermometer (circuits for reducing thermal inertia G01K 7/42) [1, 6, 2006.01] |
G01K 1/02 | UGR1 | . | Special applications of indicating or recording means, e.g. for remote indications [1, 2006.01] |
|
G01K 1/04 | UGR2 | |
G01K 1/06 | UGR3 | . . . | Arrangements for facilitating reading, e.g. illumination, magnifying glass [1, 2006.01] |
|
G01K 1/08 | UGR1 | . | Protective devices, e.g. casings [1, 2006.01] |
|
G01K 1/10 | UGR2 | . . | for preventing chemical attack [1, 2006.01] |
|
G01K 1/12 | UGR2 | . . | for preventing damage due to heat overloading [1, 2006.01] |
|
G01K 1/14 | UGR1 | . | Supports; Fastening devices; Mounting thermometers in particular locations [1, 2006.01] |
|
G01K 1/16 | UGR1 | . | Special arrangements for conducting heat from the object to the sensitive element [1, 2006.01] |
|
G01K 1/18 | UGR2 | . . | for reducing thermal inertia [1, 2006.01] |
|
G01K 1/20 | UGR1 | . | Compensating for effects of temperature changes other than those to be measured, e.g. changes in ambient temperature [1, 2006.01] |
|
G01K 1/22 | UGR2 | . . | by means of fluid contained in a hollow body having parts which are deformable or displaceable under the pressure developed by the fluid [1, 2006.01] |
|
G01K 1/24 | UGR2 | . . | by means of compounded strips or plates, e.g. bimetallic strips [1, 2006.01] |
|
G01K 1/26 | UGR1 | . | Compensating for effects of pressure changes [1, 2006.01] |
|
G01K 3/00 | HGR | Thermometers giving results other than momentary value of temperature (G01K 7/42 takes precedence) [1, 6, 2006.01] |
G01K 3/02 | UGR1 | . | giving mean values; giving integrated values [1, 2006.01] |
|
G01K 3/04 | UGR2 | . . | in respect of time [1, 2006.01] |
|
G01K 3/06 | UGR2 | . . | in respect of space [1, 2006.01] |
|
G01K 3/08 | UGR1 | . | giving differences of values; giving differentiated values [1, 2006.01] |
|
G01K 3/10 | UGR2 | . . | in respect of time, e.g. reacting only to a quick change of temperature [1, 2006.01] |
|
G01K 3/12 | UGR3 | . . . | based upon expansion or contraction of materials [1, 2006.01] |
|
G01K 3/14 | UGR2 | . . | in respect of space [1, 2006.01] |
|
G01K 5/00 | HGR | Measuring temperature based on the expansion or contraction of a material (G01K 9/00 takes precedence; giving other than momentary value of temperature G01K 3/00) [1, 2006.01] |
G01K 5/02 | UGR1 | . | the material being a liquid (G01K 5/32 takes precedence) [1, 2006.01] |
|
G01K 5/04 | UGR2 | |
G01K 5/06 | UGR3 | . . . | Arrangements for driving back the liquid column [1, 2006.01] |
|
G01K 5/08 | UGR3 | . . . | Capillary tubes [1, 2006.01] |
|
G01K 5/10 | UGR3 | . . . | Containers for the liquid [1, 2006.01] |
|
G01K 5/12 | UGR3 | . . . | Selection of liquid compositions [1, 2006.01] |
|
G01K 5/14 | UGR2 | . . | the liquid displacing a further liquid column or a solid body (for maximum or minimum indication G01K 5/20) [1, 2006.01] |
|
G01K 5/16 | UGR2 | . . | with electric contacts [1, 2006.01] |
|
G01K 5/18 | UGR2 | . . | with electric conversion means for final indication [1, 2006.01] |
|
G01K 5/20 | UGR2 | . . | with means for indicating a maximum or a minimum or both (G01K 5/22 takes precedence) [1, 2006.01] |
|
G01K 5/22 | UGR2 | . . | with provision for expansion indicating over not more than a few degrees, e.g. clinical thermometer [1, 2006.01] |
|
G01K 5/24 | UGR2 | . . | with provision for measuring the difference between two temperatures [1, 2006.01] |
|
G01K 5/26 | UGR2 | . . | with provision for adjusting zero point of scale, e.g. Beckmann thermometer [1, 2006.01] |
|
G01K 5/28 | UGR1 | . | the material being a gas (G01K 5/32 takes precedence) [1, 2006.01] |
|
G01K 5/30 | UGR2 | . . | the gas displacing a liquid column [1, 2006.01] |
|
G01K 5/32 | UGR1 | . | the material being a fluid contained in a hollow body having parts which are deformable or displaceable under the pressure developed by the material (under pressure developed by evaporation G01K 11/04) [1, 2006.01] |
|
G01K 5/34 | UGR2 | |
G01K 5/36 | UGR2 | . . | the body being a tubular spring, e.g. Bourdon tube [1, 2006.01] |
|
G01K 5/38 | UGR3 | . . . | of spiral formation [1, 2006.01] |
|
G01K 5/40 | UGR3 | . . . | of helical formation [1, 2006.01] |
|
G01K 5/42 | UGR2 | . . | the body being a bellows [1, 2006.01] |
|
G01K 5/44 | UGR2 | . . | the body being a cylinder and piston [1, 2006.01] |
|
G01K 5/46 | UGR2 | . . | with electric conversion means for final indication [1, 2006.01] |
|
G01K 5/48 | UGR1 | . | the material being a solid [1, 2006.01] |
|
G01K 5/50 | UGR2 | . . | arranged for free expansion or contraction [1, 2006.01] |
|
G01K 5/52 | UGR3 | . . . | with electrical conversion means for final indication [1, 2006.01] |
|
G01K 5/54 | UGR2 | . . | consisting of pivotally-connected elements [1, 2006.01] |
|
G01K 5/56 | UGR2 | . . | constrained so that expansion or contraction causes a deformation of the solid [1, 2006.01] |
|
G01K 5/58 | UGR3 | . . . | the solid body being constrained at more than one point, e.g. rod, plate, diaphragm (G01K 5/62 takes precedence) [1, 2006.01] |
|
G01K 5/60 | UGR4 | . . . . | the body being a flexible wire or ribbon [1, 2006.01] |
|
G01K 5/62 | UGR3 | . . . | the solid body being formed of compounded strips or plates, e.g. bimetallic strip [1, 2006.01] |
|
G01K 5/64 | UGR4 | . . . . | Details of the compound system [1, 2006.01] |
|
G01K 5/66 | UGR5 | . . . . . | Selection of composition of the components of the system [1, 2006.01] |
|
G01K 5/68 | UGR5 | . . . . . | Shape of the system [1, 2006.01] |
|
G01K 5/70 | UGR4 | . . . . | specially adapted for indicating or recording [1, 2006.01] |
|
G01K 5/72 | UGR5 | . . . . . | with electric transmission means for final indication [1, 2006.01] |
|
G01K 7/00 | HGR | Measuring temperature based on the use of electric or magnetic elements directly sensitive to heat (giving results other than momentary value of temperature G01K 3/00) [1, 2006.01] |
G01K 7/01 | UGR1 | |
G01K 7/02 | UGR1 | . | using thermo-electric elements, e.g. thermo-couples [1, 2006.01] |
|
G01K 7/04 | UGR2 | . . | the object to be measured not forming one of the thermo-electric materials [1, 2006.01] |
|
G01K 7/06 | UGR3 | . . . | the thermo-electric materials being arranged one within the other with the junction at one end exposed to the object, e.g. sheathed type [1, 2006.01] |
|
G01K 7/08 | UGR2 | . . | the object to be measured forming one of the thermo-electric materials, e.g. pointed type [1, 2006.01] |
|
G01K 7/10 | UGR2 | . . | Arrangements for compensating for auxiliary variables, e.g. length of lead [1, 2006.01] |
|
G01K 7/12 | UGR3 | . . . | Arrangements with respect to the cold junction, e.g. preventing influence of temperature of surrounding air [1, 2006.01] |
|
G01K 7/13 | UGR4 | . . . . | Circuits for cold-junction compensation [6, 2006.01] |
|
G01K 7/14 | UGR2 | . . | Arrangements for modifying the output characteristic, e.g. linearising [1, 2006.01] |
|
G01K 7/16 | UGR1 | . | using resistive elements [1, 2006.01] |
|
G01K 7/18 | UGR2 | . . | the element being a linear resistance, e.g. platinum resistance thermometer (G01K 7/26 takes precedence) [1, 2006.01] |
|
G01K 7/20 | UGR3 | . . . | in a specially-adapted circuit, e.g. bridge circuit [1, 2006.01] |
|
G01K 7/21 | UGR4 | . . . . | for modifying the output characteristic, e.g. linearising [6, 2006.01] |
|
G01K 7/22 | UGR2 | . . | the element being a non-linear resistance, e.g. thermistor (G01K 7/26 takes precedence) [1, 2006.01] |
|
G01K 7/24 | UGR3 | . . . | in a specially-adapted circuit, e.g. bridge circuit [1, 2006.01] |
|
G01K 7/25 | UGR4 | . . . . | for modifying the output characteristic, e.g. linearising [6, 2006.01] |
|
G01K 7/26 | UGR2 | . . | the element being an electrolyte [1, 2006.01] |
|
G01K 7/28 | UGR3 | . . . | in a specially-adapted circuit, e.g. bridge circuit [1, 2006.01] |
|
G01K 7/30 | UGR1 | . | using thermal noise of resistances or conductors [1, 2006.01] |
|
G01K 7/32 | UGR1 | . | using change of resonant frequency of a crystal [1, 2006.01] |
|
G01K 7/34 | UGR1 | . | using capacitative elements [1, 2006.01] |
|
G01K 7/36 | UGR1 | . | using magnetic elements, e.g. magnets, coils [1, 2006.01] |
|
G01K 7/38 | UGR2 | . . | the variations of temperature influencing the magnetic permeability [1, 2006.01] |
|
G01K 7/40 | UGR1 | . | using ionisation of gases [1, 2006.01] |
|
G01K 7/42 | UGR1 | . | Circuits for reducing thermal inertia; Circuits for predicting the stationary value of temperature [6, 2006.01] |
|
G01K 9/00 | HGR | Measuring temperature based on movements caused by redistribution of weight, e.g. tilting thermometer (not giving momentary value of temperature G01K 3/00) [1, 2006.01] |
G01K 11/00 | HGR | Measuring temperature based on physical or chemical changes not covered by group G01K 3/00, G01K 5/00, G01K 7/00, or G01K 9/00 [1, 2006.01] |
G01K 11/02 | UGR1 | . | using evaporation or sublimation, e.g. by observing boiling [1, 2006.01] |
|
G01K 11/04 | UGR2 | . . | from material contained in a hollow body having parts which are deformable or displaceable under the pressure developed by the vapour [1, 2006.01] |
|
G01K 11/06 | UGR1 | . | using melting, freezing, or softening [1, 2006.01] |
|
G01K 11/08 | UGR2 | . . | of disposable test bodies, e.g. cone [1, 2006.01] |
|
G01K 11/10 | UGR1 | . | using sintering [1, 2006.01] |
|
G01K 11/12 | UGR1 | . | using change of colour or translucency (G01K 11/32 takes precedence) [1, 6, 2006.01] |
|
G01K 11/14 | UGR2 | . . | of inorganic materials [1, 2006.01] |
|
G01K 11/16 | UGR2 | . . | of organic materials [1, 2006.01] |
|
G01K 11/18 | UGR2 | . . | of materials which change translucency [1, 2006.01] |
|
G01K 11/20 | UGR1 | . | using thermoluminescent materials (G01K 11/32 takes precedence) [1, 6, 2006.01] |
|
G01K 11/22 | UGR1 | . | using measurement of acoustic effects [1, 2006.01] |
|
G01K 11/24 | UGR2 | . . | of the velocity of propagation of sound [1, 2006.01] |
|
G01K 11/26 | UGR2 | . . | of resonant frequencies [1, 2006.01] |
|
G01K 11/28 | UGR1 | . | using measurements of density [1, 2006.01] |
|
G01K 11/30 | UGR1 | . | using measurement of the effect of a material on X-radiation, gamma radiation or particle radiation [5, 2006.01] |
|
G01K 11/32 | UGR1 | . | using changes in transmission, scattering or fluorescence in optical fibres [6, 2006.01] |
|
G01K 13/00 | HGR | Adaptations of thermometers for specific purposes [1, 2006.01] |
G01K 13/02 | UGR1 | . | for measuring temperature of moving fluids or granular materials capable of flow [1, 2006.01] |
|
G01K 13/04 | UGR1 | . | for measuring temperature of moving solid bodies [1, 2006.01] |
|
G01K 13/06 | UGR2 | . . | in linear movement [1, 2006.01] |
|
G01K 13/08 | UGR2 | . . | in rotary movement [1, 2006.01] |
|
G01K 13/10 | UGR1 | . | for measuring temperature within piled or stacked materials (by special arrangements for conducting heat from the object to the sensitive element G01K 1/16) [1, 2006.01] |
|
G01K 13/12 | UGR1 | . | combined with sampling devices for measuring temperatures of samples of material [1, 2006.01] |
|
G01K 15/00 | HGR | Testing or calibrating of thermometers [1, 2006.01] |
G01K 17/00 | HGR | Measuring quantity of heat [1, 2006.01] |
G01K 17/02 | UGR1 | . | Calorimeters using transport of an indicating substance, e.g. evaporation calorimeters [1, 2006.01] |
|
G01K 17/04 | UGR1 | . | Calorimeters using compensation methods [1, 2006.01] |
|
G01K 17/06 | UGR1 | . | Measuring quantity of heat conveyed by flowing media, e.g. in heating systems (G01K 17/02, G01K 17/04 take precedence) [1, 2006.01] |
|
G01K 17/08 | UGR2 | . . | based upon measurement of temperature difference [1, 2006.01] |
|
G01K 17/10 | UGR3 | . . . | between an inlet and an outlet point, combined with measurement of rate of flow of the medium [1, 2006.01] |
|
G01K 17/12 | UGR4 | . . . . | Indicating product of flow and temperature difference directly [1, 2006.01] |
|
G01K 17/14 | UGR5 | . . . . . | using mechanical means for both measurements [1, 2006.01] |
|
G01K 17/16 | UGR5 | . . . . . | using electrical means for both measurements [1, 2006.01] |
|
G01K 17/18 | UGR5 | . . . . . | using electrical means for one measurement and mechanical means for the other [1, 2006.01] |
|
G01K 17/20 | UGR3 | . . . | across a radiating surface, combined with ascertainment of the heat-transmission coefficient [1, 2006.01] |
|
G01K 19/00 | HGR | Testing or calibrating calorimeters [1, 2006.01] |