IPC-Stelle: F25B 43/04 [Version 7 (gültig ab 01.2000)]

SymbolTypTitel
FSKMECHANICAL ENGINEERING; LIGHTING; HEATING; WEAPONS; BLASTING
F25KLREFRIGERATION OR COOLINGCOMBINED HEATING AND REFRIGERATION SYSTEMSHEAT PUMP SYSTEMSMANUFACTURE OR STORAGE OF ICELIQUEFACTION OR SOLIDIFICATION OF GASES
F25BUKLREFRIGERATION MACHINES, PLANTS, OR SYSTEMSCOMBINED HEATING AND REFRIGERATION SYSTEMSHEAT PUMP SYSTEMS (heat-transfer, heat-exchange or heat-storage materials, e.g. refrigerants, or materials for the production of heat or cold by chemical reactions other than by combustion C09K 5/00; pumps, compressors F04; use of heat pumps for domestic or space-heating or for domestic hot-water supply F24D; air-conditioning, air-humidification F24F; fluid heaters using heat pumps F24H)
F25B 1/00ZWCompression machines, plant, or systems
F25B 1/00HGRCompression machines, plant or systems with non-reversible cycle (F25B 3/00 , F25B 5/00 , F25B 6/00 , F25B 7/00 , F25B 9/00 take precedence) [5]
F25B 1/02UGR1
.with compressor of reciprocating-piston type (F25B 1/10 takes precedence)
F25B 1/04UGR1
.with compressor of rotary type (F25B 1/10 takes precedence)
F25B 1/047UGR2
. .of screw type [5]
F25B 1/053UGR2
. .of turbine type [5]
F25B 1/06UGR1
.with compressor of jet type, e.g. using liquid under pressure (F25B 1/10 takes precedence)
F25B 1/08UGR2
. .using vapour under pressure
F25B 1/10UGR1
.with multi-stage compression (with cascade operation F25B 7/00)
F25B 3/00HGRSelf-contained rotary compression machines, i.e. with compressor, condenser, and evaporator rotating as a single unit
F25B 5/00HGRCompression machines, plant, or systems, with several evaporator circuits, e.g. for varying refrigerating capacity (with cascade operation F25B 7/00)
F25B 5/02UGR1
.arranged in parallel [5]
F25B 5/04UGR1
.arranged in series [5]
F25B 6/00HGRCompression machines, plant, or systems, with several condenser circuits [5]
F25B 6/02UGR1
.arranged in parallel [5]
F25B 6/04UGR1
.arranged in series [5]
F25B 7/00HGRCompression machines, plant, or systems, with cascade operation, i.e. with two or more circuits, the heat from the condenser of one circuit being absorbed by the evaporator of the next circuit (F25B 9/00 takes precedence)
F25B 9/00HGRCompression machines, plant, or systems, in which the refrigerant is air or other gas of low boiling point
F25B 9/02UGR1
.using Joule-Thompson effectusing vortex effect
F25B 9/04UGR2
. .using vortex effect [5]
F25B 9/06UGR1
.using expanders (F25B 9/10 takes precedence) [5]
F25B 9/08UGR1
.using ejectors (F25B 9/10 takes precedence) [5]
F25B 9/10UGR1
.with several cooling stages [5]
F25B 9/12UGR1
.using (3(He-(4(He dilution [5]
F25B 9/14UGR1
.characterised by the cycle used, e.g. Stirling cycle [5]
F25B 11/00HGRCompression machines, plant, or systems, using turbines, e.g. gas turbines
F25B 11/02UGR1
.as expanders (F25B 9/06 takes precedence) [5]
F25B 11/04UGR2
. .centrifugal type [5]
F25B 13/00HGRCompression machines, plant, or systems, with reversible cycle (defrosting cycles F25B 47/02)
F25B 15/00ZWSorption machines, plant, or systems
F25B 15/00HGRSorption machines, plant, or systems, operating continuously, e.g. absorption type
F25B 15/02UGR1
.without inert gas (F25B 15/12 , F25B 15/14 , F25B 15/16 take precedence)
F25B 15/04UGR2
. .the refrigerant being ammonia evaporated from aqueous solution
F25B 15/06UGR2
. .the refrigerant being water vapour evaporated from a salt solution, e.g. lithium bromide
F25B 15/08UGR2
. .the refrigerant being sulfuric acid
F25B 15/09UGR2
. .the refrigerant being hydrogen desorbed from a hydride [5]
F25B 15/10UGR1
.with inert gas (F25B 15/12 , F25B 15/14 , F25B 15/16 take precedence)
F25B 15/12UGR1
.with resorber (F25B 15/14 takes precedence)
F25B 15/14UGR1
.using osmosis
F25B 15/16UGR1
.using desorption cycle
F25B 17/00HGRSorption machines, plant, or systems, operating intermittently, e.g. absorption or adsorption type
F25B 17/02UGR1
.the absorbent or adsorbent being a liquid, e.g. brine (F25B 17/10 takes precedence)
F25B 17/04UGR2
. .with two or more boilers operating alternately
F25B 17/06UGR2
. .with the boiler and evaporator built-up as a unit in a tiltable or revolving arrangement
F25B 17/08UGR1
.the absorbent or adsorbent being a solid, e.g. salt (F25B 17/12 takes precedence) [5]
F25B 17/10UGR1
.using the endothermic solution of salt
F25B 17/12UGR1
.using desorption of hydrogen from a hydride [5]
F25B 19/00ZWMachines, plant, or systems, with a single mode of operation, not covered by groups F25B 1/00 to F25B 17/00
F25B 19/00HGRMachines, plant, or systems, using evaporation of a refrigerant but without recovery of the vapour
F25B 19/02UGR1
.using fluid jet, e.g. of steam
F25B 19/04UGR2
. .using liquid jet, e.g. of water
F25B 21/00HGRMachines, plant, or systems, using electric or magnetic effects
F25B 21/02UGR1
.using Peltier effectusing Nernst-Ettinghausen effect (thermoelectric elements H01L 35/00 , H01L 37/00)
F25B 21/04UGR2
. .reversible [5]
F25B 23/00HGRMachines, plant, or systems, with a single mode of operation not covered by groups F25B 1/00 to F25B 21/00 , e.g. using selective radiation effect
F25B 25/00ZWE
F25B 25/00HGRMachines, plant, or systems, using a combination of modes of operation covered by two or more of the groups F25B 1/00 to F25B 23/00 (combinations of two or more modes of operation covered by a single main group, see the relevant group)
F25B 25/02UGR1
.Compression-sorption machines, plants, or systems
F25B 27/00HGRMachines, plant, or systems, using particular sources of energy (F25B 30/06 takes precedence)
F25B 27/02UGR1
.using waste heat, e.g. from internal-combustion engines
F25B 29/00HGRCombined heating and refrigeration systems, e.g. operating alternately or simultaneously [5]
F25B 30/00HGRHeat pumps [5]
F25B 30/02UGR1
.of the compression type [5]
F25B 30/04UGR1
.of the sorption type [5]
F25B 30/06UGR1
.characterised by the source of low potential heat [5]
F25B 31/00ZWComponent parts or details
F25B 31/00HGRCompressor arrangements (compressors per se F04)
F25B 31/02UGR1
.of motor-compressor units
F25B 33/00HGRBoilersAnalysersRectifiers (boiler-absorbers F25B 35/00)
F25B 35/00HGRBoiler-absorbers, i.e. boilers usable for absorption or adsorption
F25B 35/02UGR1
.using a liquid as sorbent, e.g. brine
F25B 35/04UGR1
.using a solid as sorbent
F25B 37/00HGRAbsorbersAdsorbers (boiler-absorbers F25B 35/00; separating processes involving the treatment of liquids with adsorbents B01D 15/00; separation of gases or vapours by adsorption B01D 53/02; separation of gases or vapours by absorption B01D 53/14; investigating using adsorption or absorption G01N 30/00)
F25B 39/00HGREvaporatorsCondensers
F25B 39/02UGR1
.Evaporators
F25B 39/04UGR1
.Condensers
F25B 40/00HGRSubcoolers, desuperheaters or superheaters [5]
F25B 40/02UGR1
.Subcoolers [5]
F25B 40/04UGR1
.Desuperheaters [5]
F25B 40/06UGR1
.Superheaters [5]
F25B 41/00HGRFluid-circulation arrangements, e.g. for transferring liquid from evaporator to boiler (pumps per se, sealings therefor F04)
F25B 41/02UGR1
.using electro-osmosis
F25B 41/04UGR1
.Disposition of valves (valves per se F16K)
F25B 41/06UGR1
.Flow restrictors, e.g. capillary tubesDisposition thereof
F25B 43/00HGRArrangements for separating or purifying gases or liquids (in analysers or rectifiers F25B 33/00)Arrangements for vaporising the residuum of liquid refrigerant, e.g. by heat (F25B 40/00 takes precedence) [5]
F25B 43/02UGR1
.for separating lubricants from the refrigerant
F25B 43/04UGR1
.for withdrawing non-condensible gases
F25B 45/00HGRArrangements for charging or discharging refrigerant
F25B 47/00HGRArrangements for preventing or removing deposits or corrosion, not provided for in another subclass
F25B 47/02UGR1
.Defrosting cycles [5]
F25B 49/00HGRArrangement or mounting of control or safety devices (testing refrigerators G01M; control in general G05)
F25B 49/02UGR1
.for compression type machines, plant or systems [5]
F25B 49/04UGR1
.for sorption type machines, plant or systems [5]