IPC-Stelle: F24H 1/00 [Version 2017.01]

SymbolTypTitel
FSKMECHANICAL ENGINEERINGLIGHTINGHEATINGWEAPONSBLASTING
F24KLHEATINGRANGESVENTILATING
F24HUKLFLUID HEATERS, e.g. WATER OR AIR HEATERS, HAVING HEAT-GENERATING MEANS, IN GENERAL (heat-transfer, heat-exchange or heat-storage materials C09K 5/00; tube furnaces for thermal non-catalytic cracking C10G 9/20; devices, e.g. valves, for venting and aerating enclosures F16K 24/00; steam traps or like apparatus F16T; steam generation F22; combustion apparatus F23; domestic stoves or ranges F24B, F24C; domestic- or space-heating systems F24D; furnaces, kilns, ovens, retorts F27; heat-exchangers F28; electric heating elements or arrangements H05B)
F24H 1/00HGRWater heaters having heat generating means, e.g. boiler, flow-heater, water-storage heater (F24H 7/00, F24H 8/00 take precedence; details F24H 9/00; steam boilers F22B; domestic stoves or ranges with additional provisions for heating water F24B 9/00, F24C 13/00) [1, 5, 2006.01]
F24H 1/06UGR1
.Portable or mobile, e.g. collapsible [1, 2006.01]
F24H 1/08UGR1
.Packaged or self-contained boilers, i.e. water heaters with control devices and pump in a single unit [1, 2006.01]
F24H 1/10UGR1
.Continuous-flow heaters, i.e. heaters in which heat is generated only while the water is flowing, e.g. with direct contact of the water with the heating medium (F24H 1/50 takes precedence) [1, 5, 2006.01]
F24H 1/12UGR2
. .in which the water is kept separate from the heating medium [1, 2006.01]
F24H 1/14UGR3
. . .by tubes, e.g. bent in serpentine form [1, 2006.01]
F24H 1/16UGR4
. . . .helically or spirally coiled [1, 2006.01]
F24H 1/18UGR1
.Water-storage heaters (F24H 1/50 takes precedence; combined with water-heating stoves for central heating F24H 1/22) [1, 5, 2006.01]
F24H 1/20UGR2
. .with immersed heating elements, e.g. electric elements or furnace tubes [1, 2006.01]
F24H 1/22UGR1
.Water heaters other than continuous-flow or water-storage heaters, e.g. water heaters for central heating (F24H 1/50 takes precedence) [1, 5, 2006.01]
F24H 1/24UGR2
. .with water mantle surrounding the combustion chamber or chambers (F24H 1/40, F24H 1/44 take precedence) [1, 3, 2006.01]
F24H 1/26UGR3
. . .the water mantle forming an integral body [1, 2006.01]
F24H 1/28UGR4
. . . .including one or more furnace or fire tubes [1, 2006.01]
F24H 1/30UGR3
. . .the water mantle being built-up from sections [1, 2006.01]
F24H 1/32UGR4
. . . .with vertical sections arranged side by side [1, 2006.01]
F24H 1/34UGR2
. .with water chamber arranged adjacent to the combustion chamber or chambers, e.g. above or at side (F24H 1/24, F24H 1/44 take precedence) [1, 2006.01]
F24H 1/36UGR3
. . .the water chamber including one or more fire tubes [1, 2006.01]
F24H 1/38UGR2
. .with water contained in separate elements, e.g. radiator-type element (F24H 1/40, F24H 1/44 take precedence) [1, 2006.01]
F24H 1/40UGR2
. .with water tube or tubes (F24H 1/44 takes precedence) [1, 2006.01]
F24H 1/41UGR3
. . .in serpentine form [3, 2006.01]
F24H 1/43UGR3
. . .helically or spirally coiled [3, 2006.01]
F24H 1/44UGR2
. .with combinations of two or more of the types covered by groups F24H 1/24-F24H 1/40 [1, 2006.01]
F24H 1/46UGR1
.Water heaters having plural combustion chambers [1, 2, 5, 2006.01]
F24H 1/48UGR1
.Water heaters for central heating incorporating heaters for domestic water [5, 2006.01]
F24H 1/50UGR2
. .incorporating domestic water tanks [5, 2006.01]
F24H 1/52UGR2
. .incorporating heat exchangers for domestic water (F24H 1/50 takes precedence) [5, 2006.01]
F24H 3/00HGRAir heaters having heat generating means (F24H 7/00, F24H 8/00 take precedence; details F24H 9/00; domestic stoves or ranges with additional provisions for convection heating of air F24B, F24C) [1, 5, 2006.01]
F24H 3/02UGR1
.with forced circulation (F24H 3/12 takes precedence) [1, 2006.01]
F24H 3/04UGR2
. .the air being in direct contact with the heating medium, e.g. electric heating element [1, 2006.01]
F24H 3/06UGR2
. .the air being kept separate from the heating medium, e.g. using forced circulation of air over radiators [1, 2006.01]
F24H 3/08UGR3
. . .by tubes [1, 2006.01]
F24H 3/10UGR3
. . .by plates [1, 2006.01]
F24H 3/12UGR1
.with additional heating arrangements [1, 2006.01]
F24H 4/00HGRFluid heaters using heat pumps [5, 2006.01]
F24H 4/02UGR1
.Liquid heaters [5, 2006.01]
F24H 4/04UGR2
. .Storage heaters [5, 2006.01]
F24H 4/06UGR1
.Gas heaters [5, 2006.01]
F24H 6/00HGRCombined water and air heaters (F24H 8/00 takes precedence) [1, 5, 2006.01]
F24H 7/00HGRStorage heaters, i.e. heaters in which the energy is stored as heat in masses for subsequent release (domestic stoves or ranges with additional heat storage masses F24B 1/24, F24C 15/34) [1, 2006.01]
F24H 7/02UGR1
.the released heat being conveyed to a transfer fluid, e.g. air, water [1, 2006.01]
F24H 7/04UGR2
. .with forced circulation of the transfer fluid [1, 2006.01]
F24H 7/06UGR1
.the released heat being radiated [1, 2006.01]
F24H 8/00HGRFluid heaters having heat-generating means specially adapted for extracting latent heat from flue gases by means of condensation [5, 2006.01]
F24H 9/00HGRDetails [1, 2006.01]
F24H 9/02UGR1
.CasingsCover lidsOrnamental panels [1, 2006.01]
F24H 9/06UGR1
.Arrangement of mountings or supports [1, 2006.01]
F24H 9/12UGR1
.Connecting heaters to circulation pipes (pipe joints in general F16L) [1, 2006.01]
F24H 9/14UGR1
.Connecting different sections, e.g. in water heaters (in radiators F28F 9/26) [1, 2006.01]
F24H 9/16UGR1
.Arrangements for water drainage (valves for drainage F16K, e.g. F16K 21/00; in pipes or pipe systems in general F16L 55/00; in domestic-or space-heating systems F24D 19/08) [1, 2006.01]
F24H 9/18UGR1
.Arrangement or mounting of grates, burners, or heating elements (burners F23D; grates F23H; electric heating elements H05B) [1, 2006.01]
F24H 9/20UGR1
.Arrangement or mounting of control or safety devices (control valves F16K; safety devices for burners F23D; combustion control devices F23N; of systems comprising a heater, see the relevant subclasses, e.g. of control heating systems F24D 19/10; automatic switching for electric heating apparatus H05B 1/02) [1, 2006.01]