IPC-Stelle: F24F 13/18 [Version 7 (gültig ab 01.2000)]

SymbolTypTitel
FSKMECHANICAL ENGINEERING; LIGHTING; HEATING; WEAPONS; BLASTING
F24KLHEATINGRANGESVENTILATING (protecting plants by heating in gardens, orchards, or forests A01G 13/06; baking ovens and apparatus A21B; cooking devices other than ranges A47J; forging B21J , B21K; specially adapted for vehicles, see the relevant subclasses of classes B60 to B64; combustion apparatus in general F23; drying F26B; ovens in general F27; electric heating elements or arrangements H05B)
F24FUKLAIR-CONDITIONINGAIR-HUMIDIFICATIONVENTILATIONUSE OF AIR CURRENTS FOR SCREENING (devices for ventilating greenhouses A01G; animal husbandry A01K , e.g. controlling humidity in incubators A01K 41/04; disinfecting or sterilising of air A61L; devices for reconditioning breathing air in sealed rooms or for ventilating gasproof shelters A62B; filtering, washing or drying of gases B01D; mixing gases with vapours or liquids in general B01F 3/00; spraying B05B , B05D; removing dirt or fumes from areas where they are produced B08B 15/00; ventilation, air-conditioning, or cooling, specially adapted for vehicles, see the relevant vehicle places, e.g. B60H , B61D 27/00; production of ozone C01B 13/10; chimneys or flues E04F 17/02 , E04H 12/28 , F23J 11/00 , F23L 17/02; air ducts or conduits E04F 17/04 , F16L; ventilation in doors or windows E06B 7/02; fans, blowers F04; noise-absorbing in pipes or pipe systems F16L; tops for chimneys or ventilating shafts F23L; cooling F25; details of heat-exchange or heat-transfer apparatus, of general application F28F; apparatus for generating ions to be introduced into non-enclosed gases, e.g. the atmosphere, H01T 23/00)
F24F 1/00ZWAir-conditioning
F24F 1/00HGRRoom units, e.g. receiving primary air from a central station
F24F 1/01UGR1
.in which secondary air is induced by injector action of the primary air (F24F 1/02 takes precedence) [3]
F24F 1/02UGR1
.self-contained, i.e. with all apparatus for treatment installed in a common casing
F24F 1/04UGR2
. .Arrangements for portability
F24F 3/00HGRAir-conditioning systems in which conditioned primary air is supplied from one or more central stations to distributing units in the rooms or spaces where it may receive secondary treatmentApparatus specially designed for such systems (room units F24F 1/00; construction of heat-exchangers F28)
F24F 3/02UGR1
.characterised by the pressure or velocity of the primary air (F24F 3/044 takes precedence) [3]
F24F 3/04UGR2
. .operating with high pressure or high velocity
F24F 3/044UGR1
.Systems in which all treatment is given in the central station, i.e. all-air systems [3]
F24F 3/048UGR2
. .with temperature control at constant rate of air-flow (F24F 3/056 takes precedence) [3]
F24F 3/052UGR3
. . .Multiple duct systems, e.g. systems in which hot and cold air are supplied by separate circuits from the central station to mixing chambers in the spaces to be conditioned [3]
F24F 3/056UGR2
. .the air at least partially flowing over lighting fixtures, the heat of which is dissipated or used [3]
F24F 3/06UGR1
.characterised by the arrangements for the supply of heat-exchange fluid for the subsequent treatment of primary air in the room units (F24F 3/02 takes precedence)
F24F 3/08UGR2
. .with separate supply and return lines for hot and cold heat-exchange fluids
F24F 3/10UGR2
. .with separate supply lines and common return line for hot and cold heat-exchange fluids
F24F 3/12UGR1
.characterised by the treatment of the air otherwise than by heating and cooling (F24F 3/02 , F24F 3/06 take precedence; apparatus for the individual treatment, see the appropriate subclasses for the treatments)
F24F 3/14UGR2
. .by humidificationby dehumidification
F24F 3/147UGR3
. . .with both heat and humidity transfer between supplied and exhausted air [3]
F24F 3/153UGR3
. . .with subsequent heating, i.e. with the air, given the required humidity in the central station, passing a heating element to achieve the required temperature [3]
F24F 3/16UGR2
. .by purification, e.g. by filteringby sterilisationby ozonisation
F24F 5/00HGRAir-conditioning systems or apparatus not covered by group F24F 1/00 or F24F 3/00
F24F 6/00ZWE
F24F 6/00HGRAir-humidification [3]
F24F 6/02UGR1
.by evaporation of water in the air [3]
F24F 6/04UGR2
. .using stationary unheated wet elements [3]
F24F 6/06UGR2
. .using moving unheated wet elements [3]
F24F 6/08UGR2
. .using heated wet elements [3]
F24F 6/10UGR3
. . .heated electrically [3]
F24F 6/12UGR1
.by forming water dispersions in the air [3]
F24F 6/14UGR2
. .using nozzles (nozzles per se, spraying in general B05B) [3]
F24F 6/16UGR2
. .using rotating elements [3]
F24F 6/18UGR1
.by injection of steam into the air [3]
F24F 7/00HGRVentilation
F24F 7/007UGR1
.with forced flow (using ducting systems F24F 7/06) [3]
F24F 7/013UGR2
. .using wall or window fans, displacing air through the wall or window [3]
F24F 7/02UGR1
.Roof ventilation (F24F 7/007 takes precedence; ventilation of roof coverings E04D) [3, 6]
F24F 7/04UGR1
.with ducting systems
F24F 7/06UGR2
. .with forced air circulation, e.g. by fan
F24F 7/08UGR3
. . .with separate ducts for supplied and exhausted air [3]
F24F 7/10UGR3
. . .with air supply, or exhaust, through perforated wall, floor or ceiling (outlet members for directing or distributing air F24F 13/06) [3]
F24F 9/00HGRUse of air currents for screening, e.g. air curtain (air curtains for vehicles B60J 9/04)
F24F 11/00ZWCommon features or details
F24F 11/00HGRControl or safety systems or apparatus (control valves per se F16K) [3]
F24F 11/02UGR1
.Arrangement or mounting of control or safety devices
F24F 11/04UGR2
. .solely for controlling the rate of air-flow (F24F 11/08 takes precedence)
F24F 11/047UGR3
. . .to constant value [3]
F24F 11/053UGR3
. . .by means responsive to temperature [3]
F24F 11/06UGR2
. .solely for controlling the supply of heating or cooling fluids for secondary treatment (F24F 11/08 takes precedence)
F24F 11/08UGR2
. .for controlling the primary treatment of air
F24F 12/00HGRUse of energy recovery systems in air conditioning, ventilation or screening (with both heat and humidity transfer between supplied and exhausted air F24F 3/147; heat-exchange in general F28) [4]
F24F 13/00HGRDetails common to, or for air-conditioning, air-humidification, ventilation or use of air currents for screening
F24F 13/02UGR1
.Ducting arrangements
F24F 13/04UGR2
. .Air-mixing units (F24F 13/06 takes precedence; mixing gases in general B01F 3/02)
F24F 13/06UGR2
. .Outlets for directing or distributing air into rooms or spaces, e.g. ceiling air diffuser
F24F 13/062UGR3
. . .having one or more bowls or cones diverging in the flow direction (F24F 13/072 takes precedence) [3]
F24F 13/065UGR3
. . .formed as cylindrical or spherical bodies which are rotatable (F24F 13/072 takes precedence) [3]
F24F 13/068UGR3
. . .formed as perforated walls, ceilings or floors (F24F 13/078 takes precedence) [3]
F24F 13/072UGR3
. . .of elongated shape, e.g. between ceiling panels [3]
F24F 13/075UGR3
. . .having parallel rods or lamellae directing the outflow, e.g. the rods or lamellae being individually adjustable (F24F 13/072 takes precedence) [3]
F24F 13/078UGR3
. . .combined with lighting fixtures (air-treatment systems with air-flow over lighting fixtures F24F 3/056) [3]
F24F 13/08UGR1
.Air-flow control members, e.g. louvres, grilles, flaps, guide plates (F24F 7/013 , F24F 13/06 take precedence; roof ventilation F24F 7/02) [3]
F24F 13/10UGR2
. .movable, e.g. damper (F24F 13/18 takes precedence; valves in general F16K)
F24F 13/12UGR3
. . .built-up of sliding members
F24F 13/14UGR3
. . .built-up of tilting members, e.g. louvre
F24F 13/15UGR4
. . . .with parallel simultaneously tiltable lamellae [3]
F24F 13/16UGR3
. . .built-up of parallelly-movable plates
F24F 13/18UGR2
. .specially adapted for insertion in flat panels, e.g. in door or window-pane
F24F 13/20UGR1
.Casings or covers [5]
F24F 13/22UGR1
.Means for preventing condensation or evacuating condensate [5]
F24F 13/24UGR1
.Means for preventing or suppressing noise [5]
F24F 13/26UGR1
.Arrangements for air-circulation by means of induction, e.g. by fluid coupling or thermal effect [6]
F24F 13/28UGR1
.Arrangement or mounting of filters [6]
F24F 13/30UGR1
.Arrangement or mounting of heat-exchangers [6]
F24F 13/32UGR1
.Supports for air-conditioning, air-humidification or ventilation units [6]