IPC-Stelle: F22G [Version 7 (gültig ab 01.2000)]

SymbolTypTitel
FSKMECHANICAL ENGINEERING; LIGHTING; HEATING; WEAPONS; BLASTING
F22KLSTEAM GENERATION (chemical or physical apparatus for generating gases B01J; chemical generation of gas, e.g. under pressure, Section C; removal of combustion products or residues, e.g. cleaning of the combustion contaminated surfaces of tubes of boilers, F23J; generating combustion products of high pressure or high velocity F23R; water heaters not for steam generation F24H , F28; cleaning of internal or external surfaces of heat-transfer conduits, e.g. water tubes of boilers, F28G)
F22GUKLSUPERHEATING OF STEAM (steam-separating arrangements in boilers F22B 37/26)
F22G 1/00HGRSteam superheating characterised by heating method (exothermal chemical reactions not involving a supply of free oxygen gas, apparatus or devices for using the heat therefrom F24J)
F22G 1/02UGR1
.with heat supply by hot flue gases from the furnace of the steam boiler
F22G 1/04UGR2
. .by diverting flow or hot flue gases to separate superheaters operating in reheating cycle, e.g. for reheating steam between a high-pressure turbine stage and an intermediate turbine stage
F22G 1/06UGR1
.with heat supply predominantly by radiation
F22G 1/08UGR2
. .from heated brickwork or the like
F22G 1/10UGR1
.with provision for superheating by throttling
F22G 1/12UGR1
.by mixing steam with furnace gases or other combustion products
F22G 1/14UGR1
.using heat generated by chemical reactions
F22G 1/16UGR1
.by using a separate heat source independent from heat supply of the steam boiler, e.g. by electricity, by auxiliary combustion of fuel oil
F22G 3/00HGRSteam superheaters characterised by constructional featuresDetails or component parts thereof (general aspects of enclosed heat-exchangers F28D)
F22G 5/00HGRControlling superheat temperature (control systems for steam boilers F22B; regulating or controlling in general G05)
F22G 5/02UGR1
.Applications of combustion-control devices, e.g. tangential-firing burners, tilting burners
F22G 5/04UGR1
.by regulating flue gas flow, e.g. by proportioning or diverting
F22G 5/06UGR1
.by recirculating flue gases
F22G 5/08UGR2
. .preventing furnace gas backflow through recirculating fan
F22G 5/10UGR1
.by displacing superheater sections
F22G 5/12UGR1
.by attemperating the superheated steam, e.g. by injected water sprays (spray-mixers B01F 5/18)
F22G 5/14UGR2
. .by live steam
F22G 5/16UGR1
.by indirectly cooling or heating the superheated steam in auxiliary enclosed heat-exchanger
F22G 5/18UGR1
.by by-passing steam around superheater sections
F22G 5/20UGR1
.by combined controlling procedures
F22G 7/00HGRSteam superheaters characterised by location, arrangement, or disposition
F22G 7/02UGR1
.in fire tubes
F22G 7/04UGR1
.in jackets around fire tubes
F22G 7/06UGR1
.in furnace tubes
F22G 7/08UGR1
.in fire-boxes
F22G 7/10UGR1
.in smoke-boxes
F22G 7/12UGR1
.in flues
F22G 7/14UGR1
.in water-tube boilers, e.g. between banks of water tubes