F | SK | MECHANICAL ENGINEERING; LIGHTING; HEATING; WEAPONS; BLASTING |
F01 | USK | ENGINES OR PUMPS |
F01 | KL | MACHINES OR ENGINES IN GENERAL; ENGINE PLANTS IN GENERAL; STEAM ENGINES |
F01P | UKL | COOLING OF MACHINES OR ENGINES IN GENERAL; COOLING OF INTERNAL-COMBUSTION ENGINES (arrangements in connection with cooling of propulsion units in vehicles B60K 11/00; heat-transfer, heat-exchange or heat-storage materials C09K 5/00; heat-exchange in general, radiators F28) |
|
F01P 1/00 | HGR | Air cooling (propelling cooling-air or liquid coolants F01P 5/00; controlling supply or circulation of coolants F01P 7/00) [1, 2006.01] |
F01P 1/02 | UGR1 | . | Arrangements for cooling cylinders or cylinder heads, e.g. ducting cooling-air from its pressure source to cylinders or along cylinders [1, 2006.01] |
|
F01P 1/04 | UGR1 | . | Arrangements for cooling pistons [1, 2006.01] |
|
F01P 1/06 | UGR1 | . | Arrangements for cooling other engine or machine parts [1, 2006.01] |
|
F01P 1/08 | UGR2 | . . | for cooling intake or exhaust valves [1, 2006.01] |
|
F01P 1/10 | UGR2 | . . | for cooling fuel injectors or sparking-plugs [1, 2006.01] |
|
F01P 3/00 | HGR | Liquid cooling (propelling cooling-air or liquid coolants F01P 5/00; controlling supply or circulation of coolants F01P 7/00) [1, 2006.01] |
F01P 3/02 | UGR1 | . | Arrangements for cooling cylinders or cylinder heads [1, 2006.01] |
|
F01P 3/04 | UGR2 | . . | Liquid-to-air heat-exchangers combined with, or arranged on, cylinders or cylinder heads [1, 2006.01] |
|
F01P 3/06 | UGR1 | . | Arrangements for cooling pistons [1, 2006.01] |
|
F01P 3/08 | UGR2 | . . | Cooling of piston exterior only, e.g. by jets [1, 2006.01] |
|
F01P 3/10 | UGR2 | . . | Cooling by flow of coolant through pistons [1, 2006.01] |
|
F01P 3/12 | UGR1 | . | Arrangements for cooling other engine or machine parts [1, 2006.01] |
|
F01P 3/14 | UGR2 | . . | for cooling intake or exhaust valves [1, 2006.01] |
|
F01P 3/16 | UGR2 | . . | for cooling fuel injectors or sparking-plugs [1, 2006.01] |
|
F01P 3/18 | UGR1 | . | Arrangement or mounting of liquid-to-air heat-exchangers (such arrangements on cylinders or cylinder heads F01P 3/04; relative to vehicles B60K 11/04) [1, 2006.01] |
|
F01P 3/20 | UGR1 | . | Cooling circuits not specific to a single part of engine or machine (F01P 3/22 takes precedence) [1, 2006.01] |
|
F01P 3/22 | UGR1 | . | characterised by evaporation and condensation of coolant in closed cycles (other cooling by evaporation F01P 9/02); characterised by the coolant reaching higher temperatures than normal atmospheric boiling-point [1, 2006.01] |
|
|
F01P 5/00 | HGR | Pumping cooling-air or liquid coolants (controlling circulation or supply of coolants by influencing drive of pumps F01P 7/00) [1, 2006.01] |
F01P 5/02 | UGR1 | . | Pumping cooling-air; Arrangements of cooling-air pumps, e.g. fans or blowers [1, 2006.01] |
|
F01P 5/04 | UGR2 | . . | Pump-driving arrangements [1, 2006.01] |
|
F01P 5/06 | UGR2 | . . | Guiding or ducting air to or from ducted fans [1, 2006.01] |
|
F01P 5/08 | UGR2 | . . | Use of engine exhaust gases for pumping cooling-air [1, 2006.01] |
|
F01P 5/10 | UGR1 | . | Pumping liquid coolant; Arrangements of coolant pumps [1, 2006.01] |
|
F01P 5/12 | UGR2 | . . | Pump-driving arrangements [1, 2006.01] |
|
F01P 5/14 | UGR1 | . | Safety means against, or active at, failure of coolant-pump drives, e.g. shutting engine down; Means for indicating functioning of coolant pumps [1, 2006.01] |
|
F01P 7/00 | HGR | Controlling of coolant flow [1, 2006.01] |
F01P 7/02 | UGR1 | . | the coolant being cooling-air [1, 2006.01] |
|
F01P 7/04 | UGR2 | . . | by varying pump speed, e.g. by changing pump-drive gear ratio [1, 2006.01] |
|
F01P 7/06 | UGR2 | . . | by varying blade pitch [1, 2006.01] |
|
F01P 7/08 | UGR2 | . . | by cutting in or out of pumps [1, 2006.01] |
|
F01P 7/10 | UGR2 | . . | by throttling amount of air flowing through liquid-to-air heat-exchangers [1, 2006.01] |
|
F01P 7/12 | UGR3 | . . . | by thermostatic control [1, 2006.01] |
|
F01P 7/14 | UGR1 | . | the coolant being liquid [1, 2006.01] |
|
F01P 7/16 | UGR2 | . . | by thermostatic control [1, 2006.01] |
|
F01P 9/00 | ZWE |
|
F01P 9/00 | HGR | Cooling having pertinent characteristics not provided for in, or of interest apart from, groups F01P 1/00-F01P 7/00 (profiting from waste heat of combustion-engine cooling F02G 5/00) [1, 2006.01] |
F01P 9/02 | UGR1 | . | Cooling by evaporation, e.g. by spraying water on to cylinders (evaporation and condensation of liquid coolant in closed cycles F01P 3/22) [1, 2006.01] |
|
F01P 9/04 | UGR1 | . | by simultaneous or alternative use of direct air cooling and liquid cooling (F01P 9/02 takes precedence) [1, 2006.01] |
|
F01P 9/06 | UGR1 | . | by use of refrigerating apparatus, e.g. of compressor or absorber type [1, 2006.01] |
|
F01P 11/00 | HGR | Component parts, details, or accessories, not provided for in, or of interest apart from, groups F01P 1/00-F01P 9/00 [1, 2006.01] |
F01P 11/02 | UGR1 | . | Liquid-coolant overflow, venting, or draining devices (automatic draining during freezing conditions F01P 11/20) [1, 2006.01] |
|
F01P 11/04 | UGR1 | . | Arrangements of liquid pipes or hoses [1, 2006.01] |
|
F01P 11/06 | UGR1 | . | Cleaning (in general B08B); Combating corrosion (in general C23F) [1, 2006.01] |
|
F01P 11/08 | UGR1 | . | Arrangements of lubricant coolers (in lubrication apparatus F01M) [1, 2006.01] |
|
F01P 11/10 | UGR1 | . | Guiding or ducting cooling-air to or from liquid-to-air heat-exchangers [1, 2006.01] |
|
F01P 11/12 | UGR1 | . | Filtering, cooling, or silencing cooling-air [1, 2006.01] |
|
F01P 11/14 | UGR1 | . | Indicating devices; Other safety devices [1, 2006.01] |
|
F01P 11/16 | UGR2 | . . | concerning coolant temperature (F01P 11/20 takes precedence) [1, 2006.01] |
|
F01P 11/18 | UGR2 | . . | concerning coolant pressure, coolant flow, or liquid-coolant level [1, 2006.01] |
|
F01P 11/20 | UGR2 | . . | concerning atmospheric freezing conditions, e.g. automatically draining or heating during frosty weather [1, 2006.01] |
|