B | SK | PERFORMING OPERATIONS; TRANSPORTING |
B04 | KL | CENTRIFUGAL APPARATUS OR MACHINES FOR CARRYING-OUT PHYSICAL OR CHEMICAL PROCESSES |
B04C | UKL | APPARATUS USING FREE VORTEX FLOW, e.g. CYCLONES (exhaust or silencing apparatus for machines or engines having means for removing solid constituents of exhaust, using inertial or centrifugal separators F01N 3/037; cyclonic type combustion apparatus F23) |
B04C 1/00 | HGR | Apparatus in which the main direction of flow follows a flat spiral [1, 2006.01] |
B04C 3/00 | HGR | Apparatus in which the axial direction of the vortex remains unchanged [1, 2006.01] |
B04C 3/02 | UGR1 | . | with heating or cooling, e.g. quenching, means [1, 2006.01] |
|
B04C 3/04 | UGR1 | . | Multiple arrangement thereof [1, 2006.01] |
|
B04C 3/06 | UGR1 | . | Construction of inlets or outlets to the vortex chamber [1, 2006.01] |
|
B04C 5/00 | HGR | Apparatus in which the axial direction of the vortex is reversed [1, 2006.01] |
B04C 5/02 | UGR1 | . | Construction of inlets by which the vortex flow is generated [1, 2006.01] |
|
B04C 5/04 | UGR2 | . . | Tangential inlets [1, 2006.01] |
|
B04C 5/06 | UGR2 | . . | Axial inlets [1, 2006.01] |
|
B04C 5/08 | UGR1 | . | Vortex chamber constructions [1, 2006.01] |
|
B04C 5/081 | UGR2 | . . | Shapes or dimensions [1, 2006.01] |
|
B04C 5/085 | UGR2 | . . | with wear-resisting arrangements [1, 2006.01] |
|
B04C 5/087 | UGR2 | . . | with flexible gas-tight walls [1, 2006.01] |
|
B04C 5/10 | UGR2 | . . | with perforated walls [1, 2006.01] |
|
B04C 5/103 | UGR2 | . . | Bodies or members, e.g. bulkheads, guides, in the vortex chamber (cores B04C 5/107) [1, 2006.01] |
|
B04C 5/107 | UGR2 | . . | Cores; Devices for inducing an air-core in hydrocyclones (forming part of the outlet pipe B04C 5/13) [1, 2006.01] |
|
B04C 5/12 | UGR1 | . | Construction of the overflow ducting, e.g. diffusing or spiral exits [1, 2006.01] |
|
B04C 5/13 | UGR2 | . . | formed as a vortex finder and extending into the vortex chamber; Discharge from vortex finder otherwise than at the top of the cyclone; Devices for controlling the overflow [1, 2006.01] |
|
B04C 5/14 | UGR1 | . | Construction of the underflow ducting; Apex constructions; Discharge arrangements [1, 2006.01] |
|
B04C 5/15 | UGR2 | . . | with swinging flaps or revolving sluices; Sluices; Check-valves [1, 2006.01] |
|
B04C 5/16 | UGR2 | . . | with variable-size outlets from the underflow ducting [1, 2006.01] |
|
B04C 5/18 | UGR2 | . . | with auxiliary fluid assisting discharge [1, 2006.01] |
|
B04C 5/181 | UGR2 | . . | Bulkheads or central bodies in the discharge opening [1, 2006.01] |
|
B04C 5/185 | UGR2 | . . | Dust collectors [1, 2006.01] |
|
B04C 5/187 | UGR3 | . . . | forming an integral part of the vortex chamber [1, 2006.01] |
|
B04C 5/20 | UGR1 | . | with heating or cooling, e.g. quenching, means [1, 2006.01] |
|
B04C 5/22 | UGR1 | . | with cleaning means [1, 2006.01] |
|
B04C 5/23 | UGR2 | . . | using liquids [1, 2006.01] |
|
B04C 5/24 | UGR1 | . | Multiple arrangement thereof [1, 2006.01] |
|
B04C 5/26 | UGR2 | . . | for series flow [1, 2006.01] |
|
B04C 5/28 | UGR2 | . . | for parallel flow [1, 2006.01] |
|
B04C 5/30 | UGR2 | . . | Recirculation constructions in or with cyclones which accomplish a partial recirculation of the medium, e.g. by means of conduits [1, 2006.01] |
|
B04C 7/00 | HGR | Apparatus not provided for in group B04C 1/00, B04C 3/00 or B04C 5/00; Multiple arrangements not provided for in one of the groups B04C 1/00, B04C 3/00, or B04C 5/00; Combinations of apparatus covered by two or more of the groups B04C 1/00, B04C 3/00, or B04C 5/00 [1, 2006.01] |
B04C 9/00 | HGR | Combinations with other devices, e.g. fans (with filters for separating particles from gases or vapourĀ B01D 50/00; with dry electrostatic precipitation for separating particles from gases or vapour B03C 3/15) [1, 2006.01] |
B04C 11/00 | HGR | Accessories, e.g. safety or control devices, not otherwise provided for [1, 2006.01] |